Maestro Asia Pte Ltd
12 Woodlands Square #13-79,
Woods Square Tower One,
Singapore 737715
(+65) 8076 5747
(+65) 8484 1317
(+65) 9456 9849
enquiry@maestroasia.com.sg
Office Hours
Monday – Friday:
9am – 6pm
Sat, Sun & Public Holidays: Closed
Maestro Asia Pte Ltd
12 Woodlands Square #13-79,
Woods Square Tower One,
Singapore 737715
(+65) 8076 5747
(+65) 8484 1317
(+65) 9456 9849
enquiry@maestroasia.com.sg
Office Hours
Monday – Friday:
9am – 6pm
Sat, Sun & Public Holidays: Closed
$0.00
The online turbidity electrode adopts 90-degree scattered light method and uses a near-infrared light source to eliminate chromaticity interference and meets the IS07027 standard. The LED emits a near-infrared beam to the sample at a certain angle. The beam will emit scattering when it hits the suspended matter in the sample during transmission. The detector set at 90% of the incident light receives the scattered light. The concentration of suspended matter in the sample is The intensity of the scattered light is directly proportional, so that the concentration of suspended matter in the sample and the turbidity can be calculated by measuring the intensity of the scattered light.
We will be in contact with you within two business days.
The LED emits a near-infrared beam to the sample at a certain angle.The beam will emit scattering when it hits the suspended matter in the sample during transmission.The detector set at 90% of the incident light receives the scattered light.The concentration of suspended matter in the sample is The intensity of the scattered light is directly proportional, so that the concentration of suspended matter in the sample and the turbidity can be calculated by measuring the intensity of the scattered light.
| Model | LH-DZ09-200 | LH-DZ09-1000 | LH-DZ09-3000 |
| Measuring range | 0-200 | 0-1000 | 0-3000 |
| Resolution | 0.01,0.1,1.0 | 0.1,1.0 | 0.1,1.0 |
| Accuracy | ±0.2NTU or ±5% | ±1NTU or ±5% | ±1NTU or ±5% |
| Operating temperature | 5-40℃ | ||
| Deepest depth | Underwater 6M | ||
| Digital interface | MODBUS/RS485 | ||
| Analog interface | 4-20mA | ||
| powered by | 12VDC±20% | ||
| calibration | One point or two point | ||
| Protection class | Ip68 | ||
| Installation method | Flow tank installation or Submerged installation | ||
| size | Φ54*150mm | ||
| temperature range | -10 -50℃ | ||
| Cable length | 5M | ||
| Texture | 316 stainless steel |